862.73KB
R series Module-level Micro controller [Module-level Rapid Shutdown Device]
The Installation and Verification of V2.5 System Control (Solution R)
1.
Installation and Verification of R Series Micro Controller
2.
Installation and Verification of V2.5 Control Box DCON-S
3.
Solution R System Setting
💡
Note:Please strictly follow this guide for installation and operation, otherwise performance and warranty may be affected by some wrong operations.
1.
Product Introduction
APT-MC-R-T2(hereinafter referred to as R-T2)has 6 wires,namely PV1+ PV1-(Input),PV2+ PV2-(Input),and OUT+ OUT-(Output)
1.
PV1+ Positive Input (to panel 1)
2.
PV1- Negative Input (to panel 1)
3.
OUT- Negative Output (to adjacent R-T2)
4.
PV2- Negative Input (to panel 2)
5.
PV2+ Positive Input (to panel 2)
6.
OUT+ Positive Output (to adjacent R-T2)
Yellow casing on the PV1 terminals; White casing on the PV2 terminals;
Red casing on the OUT terminals
7.
Scan the QR code to obtain the device SN number